Small, rectangular, pulse-tube ADR cryostat


Features:


Specifications:

102 Denali ADR Cryostat, Cryocooler

Section view of 102 Denali ADR cryostat showing pulse-tube head, adiabatic demagnetazition refrigerator, high temp superconducting leads for 4T magnet, thermal shielding, mechanical heat switch.

102 Denali ADR Cryostat, Cryocooler

Interior view of 102 Denali ADR cryostat on a service stand, showing pulse-tube head, thermal links at 50K and 3K stages, detector mounts, vibration isolation bellows.

102 Denali ADR Cryostat, Cryocooler

Model 102 Denali ADR cryostat on Atlas 100 service stand.

102 Denali cryostat

Model 102 Denali ADR cryostat on Atlas 100 service stand.

102 Denali cryostat

Cross-section of 102 Denali cryostat showing pulse-tube cooler, ADR stage, and thermal shields.

102 Denali cryostat

Top view of 102 Denali cryostat showing pulse tube cooler and feedthroughs.

102 Denali ADR Cryostat, Cryocooler

Typical cooling cycle for pulse-tube cooled ADR cryostat.

Compare ADR Cryostat Models

102 Cryostat 103 Cryostat 104 Cryostat 106 Cryostat 107 Cryostat 124 Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube, He-3 Backed, Single Stage ADR Cryostat
Tabletop GM Cooler Two Stage ADR Cryostat
Vacuum Jacket Size
33 cm X 22 cm X
66 cm Tall
Vacuum Jacket Size
Ø 35 cm X 69 cm Tall
Vacuum Jacket Size
Ø 55 cm X 110 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Experimental Volume
24 cm X 15 cm X
14 cm Tall
Experimental Volume
Ø 26 cm X 25 cm Tall
Experimental Volume
Ø 44 cm X 60 cm Tall
Experimental Volume
Ø 34 cm X 21 cm Tall
Experimental Volume
Ø 34 cm X 20 cm Tall
Experimental Volume
Ø 34 cm X 20 cm Tall
1st Stage Cooling Power
25 W @ 55 K
1st Stage Cooling Power
25 W @ 55 K
1st Stage Cooling Power
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
25 W @ 55 K
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
25 W @ 55 K
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
40 W @ 55 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
2nd Stage Cooling Power
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
1.5 W @ 4.2 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
He-3 Cooling Capacity
6 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 30 mK
ADR Base Temperature
< 50 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
200 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
Click HERE to learn more from an HPD sales engineer...
High Precision Devices, Inc.
1668 Valtec Lane, Suite C Boulder, CO 80301 USA
Phone: +1-303-447-2558 Email: info@hpd-online.com Cage Code: 3JNM0