The 103 RapidCool Cryostat (RCC) accelerates cooldown from room temperature to 4 K in just 4 hours (compared to a typical cooldown time of 13 hours). The 103 RapidCool provides all of the benefits of our popular 103 Rainier cryostat, and also allows you to expedite your experimentation, without delay. You get the best of all worlds: a compact, cylindrical cryostat with a large experimental space; plus, super-fast liquid nitrogen cooldown and insulated inlet/outlet lines that prevent frost formation. In addition, our RapidCool features can be used as options on other HPD cryostat models. Call us to discuss your needs.

Features:

Specifications:

103 RapidCool ADR Cryostat, Cryocooler
103 RapidCool ADR Cryostat, Cryocooler

Typical Model 103 RapidCool Cryostat

103 RapidCool cryostat

Top view of 103 RapidCool Cryostat, showing pulse-tube cooler, feedthrough flanges, and LN2 inlet and outlet lines.

103 Cryostat, Cooling Comparison

Compare ADR Cryostat Models

102 Cryostat 103 Cryostat 104 Cryostat 106 Cryostat 107 Cryostat 124 Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube, He-3 Backed, Single Stage ADR Cryostat
Tabletop GM Cooler Two Stage ADR Cryostat
Vacuum Jacket Size
33 cm X 22 cm X
66 cm Tall
Vacuum Jacket Size
Ø 35 cm X 69 cm Tall
Vacuum Jacket Size
Ø 55 cm X 110 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Experimental Volume
24 cm X 15 cm X
14 cm Tall
Experimental Volume
Ø 26 cm X 25 cm Tall
Experimental Volume
Ø 44 cm X 60 cm Tall
Experimental Volume
Ø 34 cm X 21 cm Tall
Experimental Volume
Ø 34 cm X 20 cm Tall
Experimental Volume
Ø 34 cm X 20 cm Tall
1st Stage Cooling Power
25 W @ 55 K
1st Stage Cooling Power
25 W @ 55 K
1st Stage Cooling Power
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
25 W @ 55 K
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
25 W @ 55 K
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
40 W @ 55 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
2nd Stage Cooling Power
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
1.5 W @ 4.2 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
He-3 Cooling Capacity
6 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 30 mK
ADR Base Temperature
< 50 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
200 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK