Model 104 Olympus adiabatic demagnetization refrigerator (ADR) is a large cryostat that provides an experimental space of 44 cm in diameter and 60 cm tall.
HPD’s attention to detail provides many high-quality cryogenic features, including cool down from 300 K to 4 K in just 16 hours, a vibration minimizing design, and 150 hours no-load regulation at 100 mK.
Furthermore, the Model 104 Olympus can also be reconfigured for your specific project.
*Optional pulse tube
+Default pulse tube
Vacuum Jacket Size
Ø 55 cm X 110 cm tall
Experimental Volume
Ø 44 cm X 60 cm tall
Cool down from 300 K to 4 K in 16 hours
1st Stage Cooling Power
36 W @ 45 K*, 40 W @ 45 K+
2nd Stage Cooling Power
0.9 W @ 4.2 K*, 1.35 W @ 4.2 K+
GGG Cooling Capacity
1.2 J @ 1 K
FAA Cooling Capacity
120 mJ @ 100 mK
ADR Base Temperature
50 mK
150 hour no-load regulation at 100 mK
Vacuum Jacket Size
33 cm X 22 cm X 66 cm tall
Experimental Volume
24 cm X 15 cm X 14 cm tall
Cool down from 300 K to 4 K in 12 hours
1st Stage Cooling Power
22 W @ 55 K
2nd Stage Cooling Power
0.6 W @ 4.2 K
GGG Cooling Capacity
1.2 J @ 1 K
FAA Cooling Capacity
120 mJ @ 100 mK
ADR Base Temperature
50 mK
150 hour no-load regulation at 100 mk
Vacuum Jacket Size
Ø 35 cm X 69 cm tall
Experimental Volume
Ø 26 cm X 25 cm tall
Cool down from 300 K to 4 K in 15 hours
1st Stage Cooling Power
22 W @ 55 K
2nd Stage Cooling Power
0.6 W @ 4.2 K
GGG Cooling Capacity
1.2 J @ 1 K
FAA Cooling Capacity
120 mJ @ 100 mK
ADR Base Temperature
50 mK
250 hour no-load regulation at 100 mK
Vacuum Jacket Size
Ø 44 cm X 65 cm tall
Experimental Volume
Ø 34 cm X 21 cm tall
Cool down from 300 K to 4 K in 16 hours
1st Stage Cooling Power
22 W @ 55 K*, 36 W @ 45 K+, 40 W @ 45 K*
2nd Stage Cooling Power
0.6 W @ 4.2 K*, 0.9 W @ 4.2 K+, 1.35 W @ 4.2 K*
GGG Cooling Capacity
1.2 J @ 1 K
FAA Cooling Capacity
120 mJ @ 100 mK
ADR Base Temperature
50 mK
250 hour no-load regulation at 100 mK
Vacuum Jacket Size
Ø 44 cm X 65 cm tall
Experimental Volume
Ø 34 cm X 20 cm tall
1st Stage Cooling Power
22 W @ 55 K*, 36 W @ 45 K+, 40 W @ 45 K*
2nd Stage Cooling Power
0.6 W @ 4.2 K*, 0.9 W @ 4.2 K+, 1.35 W @ 4.2 K*
3He Cooling Capacity
6 J @ 1 K
FAA Cooling Capacity
200 mJ @ 100 mK
ADR Base Temperature
30 mK
300 hour no-load regulation at 100 mK
Vacuum Jacket Size
Ø 55 cm X 110 cm tall
Experimental Volume
Ø 38 cm X 19 cm tall
1st Stage Cooling Power
40 W @ 45 K
2nd Stage Cooling Power
1.5 W @ 4.2 K
Lower Stages
1.5 K, 0.6 K Still, 0.1 K Cold Plate
Mixing Chamber Base Temperature
30 mK
Mixing Chamber Cooling Power
200 µW @ 100 mK
*Optional pulse tube
+Default pulse tube
*Optional pulse tube
+Default pulse tube
*Optional pulse tube
+Default pulse tube
*Optional pulse tube
+Default pulse tube
Interested in our other ADR cryostats?
High Precision Devices is the leader in precision cryogenic instrument development. We also proudly engineer and sell environmental monitors, laser power meters, and more.
Cryogenic Products
More Products
About HPD